邵双全, 博士, 教授, 华中科技大学能源与动力工程学院,13520177661,E-mail:shaoshq@hust.edu.cn。研究方向:高效热湿环境控制理论及其在舒适性空调、食品保质贮运加工全程冷链、 电子产品及数据中心冷却等方面应用的关键技术研究。Shao Shuangquan, Ph.D., professor, School of Energy and Power Engineering, Huazhong University of Science and Technology, 86-13520177661, E-mail: shaoshq@hust.edu.cn. Research fields: theory of efficient thermal-humidity environment control and its key technology applications in comfort air-conditioning, full-chain cold chain for food quality preservation during storage, transportation and processing, as well as cooling of electronic products and data centers.
修回:2025-06-02,
录用:2025-06-04,
网络首发:2026-02-09,
移动端阅览
李长智,唐少瀛,谢冬梅等.湖水自然冷却数据中心制冷系统模拟与优化研究[J].制冷学报,
Li Changzhi,Tang Shaoying,Xie Dongmei,et al.Simulation and Optimization of Data-Center Cooling System with Naturally Cooled Reservoir Water[J].Journal of Refrigeration,
李长智,唐少瀛,谢冬梅等.湖水自然冷却数据中心制冷系统模拟与优化研究[J].制冷学报, DOI:10.12465/issn.0253-4339.20250522003. CSTR: XXXXX.XX.XXX.20250522003.
Li Changzhi,Tang Shaoying,Xie Dongmei,et al.Simulation and Optimization of Data-Center Cooling System with Naturally Cooled Reservoir Water[J].Journal of Refrigeration, DOI:10.12465/issn.0253-4339.20250522003. CSTR: XXXXX.XX.XXX.20250522003.
随着数据中心向智算化转型,单机柜功耗密度提升,冷却能耗占比高,降低数据中心电能使用效率至关重要。本文提出一种结合自然水源与液冷技术的冷却系统,以广西来宾某数据中心为研究对象,构建系统模型,分析不同控制方式和运行条件下的系统性能,并与常规水冷冷水机组冷却系统对比。研究表明:冷冻水泵控制送风温度能耗更低,节能约10% 且利于余热利用;冷却水泵控制冷冻水供水温度更节能,但节能率随水库水温的升高而下降;自然水源冷却系统全年节能率达73.5%,制冷负载系数为0.05,低于常规系统;送风温度设定点高时系统能耗波动小,综合考虑选取 28 ℃较合适。该研究为绿色节能数据中心冷却系统设计提供了参考。
Owing to the transformation of data centers toward intelligent computing, the power density per cabinet has increased, with cooling-energy consumption constituting a significant proportion. Reducing the power-usage effectiveness (PUE) of data centers is crucial. This study proposes a cooling system that combines natural water sources with liquid-cooling technology. Considering a data center in Laibin, Guangxi as the research object, a system model is constructed to analyze the system performance under different control methods and operating conditions; subsequently, it is compared with conventional water-cooled chiller cooling systems. The result shows that controlling the supply-air temperature through the chilled-water pump reduces energy consumption by approximately 10% energy as well as facilitates waste-heat utilization. Additionally, controlling the chilled water-supply temperature through the cooling water pump is more energy efficient, although the energy-saving rate decreases as the reservoir water temperature increases. The natural water-source cooling system achieves an annual energy-saving rate of 73.5% with a cooling load factor of 0.05, which is lower than that of the conventional system. When the supply-air temperature setpoint is higher, the system energy consumption fluctuates less. Based on a comprehensive consideration, 28 ℃ is a suitable temperature. This study provides a reference for the design of green and energy-efficient data-center cooling systems.
Kargar S , Moran J L . Combining direct and indirect free cooling for data centers via transformation into a building-scale heat exchanger [J]. Applied Energy , 2025 , 392 : 125973 .
Borkowski M , Piłat A K . Customized data center cooling system operating at significant outdoor temperature fluctuations [J]. Applied Energy , 2022 , 306 ( Part B ): 117975
Fan Chengliang , Zou Binwei , Liao Yundan , et al . Evaluation of energy performance and ecological benefit of free-cooling system for data centers in worldwide climates [J]. Sustainable Cities and Society , 2024 , 108 : 105509 .
陈石鲁 , 张小松 , 赵善国 . 基于蒸发冷却的数据中心热管背板空调系统研究 [J]. 制冷学报 , 2023 , 44 ( 5 ): 32 - 40 .
Chen Shilu , Zhang Xiaosong , Zhao Shanguo . Research on heat-pipe backplane air-conditioning system based on evaporative cooling in data center [J]. Journal of Refrigeration , 2023 , 44 ( 5 ): 32 - 40 .
严政 , 吴学渊 , 黄翔 , 等 . 水侧自然冷却技术在雄安城市计算中心的应用研究 [J]. 建筑科学 , 2023 , 39 ( 1 ): 93 - 100 .
Yan Zheng , Wu Xueyuan , Huang Xiang , et al . Application of water side natural cooling technology in Xiongan Urban Computing Center [J]. Building Science , 2023 , 39 ( 1 ): 93 - 100 .
Ma Shuaiyin , Liu Yuyang , Liu Yang , et al . Artificial intelligence-enabled predictive energy saving planning of liquid cooling system for data centers [J]. Advanced Engineering Informatics , 2025 , 65 : 103283 .
Samal S K , Chang H C , Fulpagare Y , et al . Thermal management of data centers: Chip-scale cooling using novel distributed inlet-outlet jet impingement liquid cold plate [J]. Applied Thermal Engineering , 2025 , 271 : 126360 .
Miao Jie , Li Chao , Pan Minqiang . Experimental and numerical analysis of variable cross-section channel liquid cooling plate for server chips thermal management [J]. Thermal Science and Engineering Progress , 2024 , 49 : 102470 .
Silva-Llanca L , Ponce C , Bermúdez E , et al . Improving energy and water consumption of a data center via air free-cooling economization: The effect weather on its performance [J]. Energy Conversion and Management , 2023 , 292 : 117344 .
Cho J , Lim T , Kim B S . Viability of datacenter cooling systems for energy efficiency in temperate or subtropical regions: Case study [J]. Energy and Buildings , 2012 , 55 : 189 - 197 .
Mi Ranran , Bai Xuelian , Xu Xin , et al . Energy performance evaluation in a data center with water-side free cooling [J]. Energy and Buildings , 2023 , 295 : 113278 .
Cheung H , Wang Shengwei . Optimal design of data center cooling systems concerning multi-chiller system configuration and component selection for energy-efficient operation and maximized free-cooling [J]. Renewable Energy , 2019 , 143 : 1717 - 1731 .
Qu Shengli , Duan Kaiwen , Guo Yuxiang , et al . Real-time optimization of the liquid-cooled data center based on cold plates under different ambient temperatures and thermal loads [J]. Applied Energy , 2024 , 363 : 123101 .
Heydari A , Gharaibeh A R , Tradat M , et al . Experimental evaluation of direct-to-chip cold plate liquid cooling for high-heat-density data centers [J]. Applied Thermal Engineering , 2024 , 239 : 122122 .
何平 , 卢浩 , 范益伟 , 等 . 工字形流道液冷板式换热器用于电池热管理的数值研究 [J]. 制冷学报 , 2023 , 44 ( 5 ): 78 - 87 .
He Ping , Lu Hao , Fan Yiwei , et al . Numerical investigation of battery thermal management using liquid-cooling plate exchanger with I-shaped flow channel [J]. Journal of Refrigeration , 2023 , 44 ( 5 ): 78 - 87 .
Pan Chaofeng , Wu Jiaxin , Wang Jian , et al . Topology optimization-based design and performance analysis of liquid cooling plates for lithium-ion batteries [J]. Journal of Energy Storage , 2025 , 124 : 116842 .
Zhang Furen , Wang Yufeng , Li Xue , et al . Thermal characteristics and optimization of a novel liquid cooling plate with cavities and flow-enhancing fins [J]. International Communications in Heat and Mass Transfer , 2025 , 165 : 109042 .
Hnayno M , Chehade A , Klaba H , et al . Performance analysis of new liquid cooling topology and its impact on data centres [J]. Applied Thermal Engineering , 2022 , 213 : 118733 .
罗海亮 , 李印 , 王学军 . 数据中心冷却系统的温度与温差浅析 [J]. 制冷与空调(北京) , 2021 , 21 ( 5 ): 83 - 88 .
Luo Hailiang , Li Yin , Wang Xuejun . Analysis on temperature and temperature difference of data center cooling system [J]. Refrigeration and Air-conditioning , 2021 , 21 ( 5 ): 83 - 88 .
0
浏览量
0
下载量
0
CSCD
关联资源
相关文章
相关作者
相关机构
京公网安备11010802024621