引用本文
  •    [点击复制]
  •    [点击复制]
【打印本页】 【下载PDF全文】 查看/发表评论下载PDF阅读器关闭

←前一篇|后一篇→

过刊浏览    高级检索

本文已被:浏览 1892次   下载 1947 本文二维码信息
码上扫一扫!
基本型脉管内气体振荡制冷机理的分子动力学模拟
王禹贺, 祁影霞, 车闫瑾, 陈曦, 张华
0
(上海理工大学能源与动力工程学院)
摘要:
脉管制冷机在当今社会应用广泛,但目前对脉管内部气体流动的热力动态过程缺乏微观机理研究。本文采用分子动力学模拟方法,建立通道模型,并对通道内进行充气和放气,模拟脉管的压缩和膨胀,进而研究脉管轴向压力、密度、速度和温度随时间的变化。结果表明:随着过程进行,气体轴向的压力与密度梯度逐渐减小,直至达到平衡,但会出现略微的逆向梯度。膨胀和压缩过程在64 ps时,在通道出口附近出现最大速度,分别为775 m/s和864 m/s,且随着反应的进行,最大速度处逐渐向压力低的方向移动。通道内各点压力波与速度波的相位随位置而变。在压缩过程中,通道内靠近封闭端温度较高,可高达500 K,远离封闭端温度较低,可以降至223 K,膨胀过程则相反;一次循环温度场叠加时,在热端处,时间积分的平均值为375 K,在冷端处,时间积分的平均值为244 K,因而有利于热端向环境散热和冷端制冷。
关键词:  分子动力学模拟  脉管低温制冷机  热力学性质  相位
DOI:
投稿时间:2017-11-16  修订日期:2018-02-06  
基金项目:
Molecular Dynamic Simulation of Gas-oscillation Refrigeration Mechanism in a Basic-type Pulse Tube
Wang Yuhe, Qi Yingxia, Che Yanjin, Chen Xi, Zhang Hua
(School of Energy and Power Engineering, University of Shanghai for Science and Technology)
Abstract:
Pulse-tube refrigerators are widely used in our society today, but research on the microscopic mechanism of the dynamic process of gas flow inside the pulse tube is lacking. In this study, the molecular dynamic simulation method was used to establish a channel model, and the channel was inflated and deflated to simulate the compression and expansion of a pulse tube. Subsequently, with variations in time, the axial pressure, density, velocity, and temperature of the pulse tube were studied. The results show that the pressure and density gradient in the axial direction of the gas gradually decreased until a balance was reached when the process continued, but a slight reversed gradient occurred. Expansion and compression processes occurred at 64 ps, and the maximum velocities near the channel exit were 775 and 864 m/s, respectively. As the reaction progressed, the maximum velocity gradually moved toward lower pressure. The phases of the pressure and velocity waves in the channel varied with the position. In the compression process, the high temperature of the channel near the closed end reached up to 500 K. Simultaneously, the temperature away from the closed end could be reduced to 223 K, and the expansion process was opposite that in the previous condition. The average time integral at the hot end was 375 K at the time of one temperature cycle superposition, and the average time integral at the cold end was 244 K. Thus, cooling of the environment at the hot and cold ends of refrigeration was facilitated.
Key words:  molecular dynamics simulation  pulse tube cryogenic cryocooler  thermodynamic properties  phase

用微信扫一扫

用微信扫一扫