WANG ZHENHUAN, CHOI YOUNSUNG, WANG SHANSHAN. Experimental and Numerical Investigation of a Refrigerator Unit for a Refrigerated Vehicle. [J]. Journal of refrigeration, 2024, 45(1).
WANG ZHENHUAN, CHOI YOUNSUNG, WANG SHANSHAN. Experimental and Numerical Investigation of a Refrigerator Unit for a Refrigerated Vehicle. [J]. Journal of refrigeration, 2024, 45(1). DOI: 10.3969/j.issn.0253-4339.2024.01.129.
To examine the influence of different parameters of a 10 kW refrigeration unit on the performance of a refrigerated vehicle
the capacity
coefficient of performance (COP)
and pressure performance of the circulation system of a refrigeration unit were tested using experimental and simulation methods. Additionally
changes were made to the refrigerant charge
degree of superheating
and refrigerant type to conduct experimental and simulation studies. The results showed that the capacity and COP of the refrigeration unit exhibited different trends with changes in the refrigerant charge and superheat. The cooling capacity and COP errors between simulation and experiment were 6.4% and 8.5%
respectively
and the error of all results was within 10%. It was confirmed that the performance variation in the refrigeration unit was more sensitive to the variation in the degree of superheating than to the refrigerant charge. The best capacity and COP were achieved when the degree of superheat was 4 ℃ and the refrigerant charge was 7.4 kg. Furthermore
through numerical simulation
it was determined that the COP performance of the refrigerant R449A
used in the refrigeration cycle system
was approximately 4% higher than that of R404A. It was confirmed that the refrigerant R449A can be used instead of R404A.
关键词
冷藏车制冷机组制冷能力过热度COPR449A
Keywords
refrigerated vehiclerefrigeration unitcooling capacitydegree of superheatCOPR449A