GUO FUCHENG, LI YANZHONG, LI CUI. Numerical Comparisons of Temperature-controlling Characteristics between Semi- and Holo-TMP Structures in Cryotarget System. [J]. Journal of refrigeration, 2023, 44(1).
GUO FUCHENG, LI YANZHONG, LI CUI. Numerical Comparisons of Temperature-controlling Characteristics between Semi- and Holo-TMP Structures in Cryotarget System. [J]. Journal of refrigeration, 2023, 44(1). DOI: 10.3969/j.issn.0253-4339.2023.01.081.
The temperature-controlling characteristics of a thermal mechanical package (TMP) are crucial to the experiments in inertial confinement fusion. This study addresses the semi- and holo-TMP structures. The influences of relative factors
including the pressure of helium inside the hohlraum
width of bulge loops
and power of heat rings
on the temperature-controlling characteristics of TMP are investigated systematically. The results show that a semi-TMP structure has a better temperature-control performance than a holo-structure under the same thermal conditions. Increasing the pressure of helium makes a positive but limited contribution to the TMP temperature-control effect. The presence of bulge loops enhances the heat transfer between the TMP and gold hohlraum
thereby improving the temperature-control performance. In addition
the widths of the bulge loops slightly improve the temperature-controlling effect. The temperature response of the gold hohlraum to variations in the heat ring power exhibits clear differences between the semi- and holo-TMP structures. As the heating power increases
the maximum temperature difference of the gold hohlraum increases linearly at a rate of 0.38 K/W and 0.25 K/W for the semi- and the holo-TMP structures
respectively
which indicates a better temperature-controlling effect on the semi-TMP structure.