LIU MINGKANG, SU LIN, FANG YIDONG, et al. Experimental Investigation on Heating Performance of Heat Pump Air-conditioning System for Electric Vehicle in Winter. [J]. Journal of refrigeration, 2020, 41(4).
LIU MINGKANG, SU LIN, FANG YIDONG, et al. Experimental Investigation on Heating Performance of Heat Pump Air-conditioning System for Electric Vehicle in Winter. [J]. Journal of refrigeration, 2020, 41(4). DOI: 10.3969/j.issn.0253-4339.2020.04.045.
The heating performance of a three-heat exchanger heat pump air-conditioning system of an electric vehicle in winter is investigated experimentally. The effects of indoor
outdoor ambient temperatures and relative humidity on the outlet temperature of the heating ventilation and air conditioning (HVAC) module
coefficient of performance (COP) and other performance parameters are investigated at different compressor speeds. The results show that higher compressor speeds can improve the outlet air temperature and heating capacity of the HVAC module
but the COP of the system decreases. When the compressor speed is maintained constant
for every 5 ℃ increase in the ambient temperature
the heating capacity increases by 9%–22%
the outlet temperature increases by 6–9 ℃
and COP increases by 7%–11%. When the outdoor relative humidity increases from 40% to 80%
the heating capacity increases by 15%–20%
outlet temperature increases by 2–3 ℃
and the COP increases by 6%–9%.
关键词
电动汽车空调热泵HVAC总成采暖性能能效系数
Keywords
electric vehicle air-conditiondingheat pumpHVAC moduleheating performancecoefficient of performance