When an air source heat pump water heater runs at higher water temperature
the power input and the discharge temperature of its compressor are high
leading to problems of security and stability
and the significant decrease of the system efficiency.In our study
a hot water system with a two-stage condensation heat pump and its corresponding control method were proposed.The experimental results show that compared with the conventional heat pump water heaters
the present system can raise the temperature of sup...
Yildiz Kalinci,Arif Hepbasli.A review of heat pump water heating systems[J].Renewable & sustainable energy reviews.2009,13(6).
J. Zhang,J. Y. Wu,R. Z. Wang.System optimization and experimental research on air source heat pump water heater[J].Applied thermal engineering: Design, processes, equipment, economics.2007,27(5).
Yang Wang,Yiqiang Jiang,Huimin Jiang,等.An experimental study on a modified air conditioner with a domestic hot water supply (ACDHWS)[J].Energy.2006,31(12).
T. Anderson,M. Behnia,G.L. Morrison.Seasonal performance rating of heat pump water heaters[J].太阳能.2004,76(1).