Liu Lu, Zhan Feilong, Ding Guoliang, et al. Experimental Comparison on Distribution Uniformity Among Different Types of Refrigerant Distributors Used in Air-conditioners[J]. Journal of refrigeration, 2022, 43(6).
DOI:
Liu Lu, Zhan Feilong, Ding Guoliang, et al. Experimental Comparison on Distribution Uniformity Among Different Types of Refrigerant Distributors Used in Air-conditioners[J]. Journal of refrigeration, 2022, 43(6). DOI: 10.3969/j.issn.0253-4339.2022.06.025.
Experimental Comparison on Distribution Uniformity Among Different Types of Refrigerant Distributors Used in Air-conditioners
When selecting the type of pressure-drop distributor for air conditioners with good distribution performance
the divergence of the distribution uniformity among the existing types of pressure-drop distributors should be checked. In this study
an experimental rig for testing the distribution homogeneity of distributors was designed and established. Thereafter
the distribution unevenness of existing reflection-type
jet loop-type
Venturi-type
and filter-type distributors were measured and compared. The testing conditions include a refrigerant volumetric flow rate of 32–125 L/h and a vapor quality of 0.15–0.22
which represent the normal operating conditions of room air conditioners. The installation angle of the distributor between the central axis of the distributor and the vertical direction ranged from 0° to 90°. The results demonstrate that a large mass flow rate of the inlet refrigerant or the vertical installation of the distributor is beneficial to distribution uniformity. The filter-type distributor exhibited good distribution uniformity under various experimental conditions
with a distribution unevenness of less than 0.05. Thus
the filter-type distributor is most suitable for air conditioners.
Structure Optimization of Connecting Tubes of Distributor for Improving the Distribution Uniformity of Refrigerant
Effects of Mixer Length and Diffuser Angle on Two-Phase CO2 Ejector
Experimental Investigation on Two-Phase Flow Pattern of Hydrocarbon Refrigerants in the Shell Side of a Helically Baffled Shell and Tube Heat Exchanger
Adiabatic and Boiling Liquid-vapor Flow Pressure Drop in a Serpentine Microchannel
Correction Method of Two-phase Flow Heat Transfer and Pressure Drop in Micro-channel Parallel Flow Condenser
Related Author
Xu Xuefei
Gao Zheming
Liu Lu
Liu Yantao
Chen Jiangping
Long Junan
Pan Meina
Shi Junye
Related Institution
GD Midea Refrigeration Equipment Co, Ltd
Shanghai High Efficient Cooling System Research Center
Nanjing University of Aeronautics and Astronautics
Institute of Refrigeration and Cryogenics, Shanghai Jiao Tong University