RONG JUN, WANG YICHUN, WANG RUIJUN, et al. Cooling Performance of Air Conditioning Systems with Non-contact Thermal Resistance Aluminum Heat Exchanger. [J]. Journal of refrigeration, 2014, 35(4).
DOI:
RONG JUN, WANG YICHUN, WANG RUIJUN, et al. Cooling Performance of Air Conditioning Systems with Non-contact Thermal Resistance Aluminum Heat Exchanger. [J]. Journal of refrigeration, 2014, 35(4). DOI: 10.3969/j.issn.0253-4339.2014.04.099.
Cooling Performance of Air Conditioning Systems with Non-contact Thermal Resistance Aluminum Heat Exchanger
In order to replace the traditional heat exchanger of room air conditioner
a new non-contact thermal resistance aluminum heat exchanger was designed. Enthalpy method is then used to compare the cooling performance between new heat exchanger and tube-fin heat exchanger of household air conditioner. The capillary size and refrigerant charge capacity of air conditioner are tested and optimized for better cooling performance. The results show that the heat transfer area of the new non-contact thermal resistance aluminum heat exchanger is decreased 37.53%
the rated cooling capacity is just reduced by 2.7%
EER increased by 7% instead. The new heat exchanger has a stronger heat capacity and is the ideal alternative product for heat exchangers of room air conditioners.