Cite this article
  •    [Click To Copy]
  •    [Click To Copy]
【Print This Page】 【Download PDF Full Text】 View/Add CommentDownload reader Close

←Previous Article|Next Article→

Back Issue    Advanced Search

This Article Has Been:Browse 221 Times   Download 187 Times QR code information in this article
Scan Up The Code!
基于冰浆制冷的标准冷源及不确定度分析
梁勇彪1, 许戈耀1, 谢宇航1, 周龙1, 钟武槟2, 李斌诚3, 巫江虹1
0
(1.华南理工大学机械与汽车工程学院;2.广州群创电气设备技术有限公司;3.威凯检测技术有限公司)
摘要:
房间空调器制冷量的计量结果在不同焓差室间不一致的问题仍困扰着中国空调行业,是国际贸易中容易引发纠纷的计量学问题,亟待研究可对焓差实验室进行标定的标准冷源。在研究国内外房间空调器几种主流的制冷量计量方法以及标准冷源研究现状的基础上,结合对冰浆制冷物理过程的深入理解,提出基于冰浆制冷的标准冷源装置,包括冰浆制备系统和换热系统两大部分。对其进行实验研究及制冷量不确定度分析,验证该标准冷源装置是否具备标定焓差实验室的能力。实验结果表明:在焓差室室外侧为0 ℃,室内侧为标准制冷工况, m ?=70 g/s下该标准冷源装置输出制冷量的相对不确定度可以达到1.2%,约为空气焓值法的1/3,可作为标准冷源对焓差室的制冷量测量结果进行标定,有助于提高制冷行业的国际竞争力。
关键词:  冰浆制冷  标准冷源  焓差室  空气焓值法  校准  相对不确定度
DOI:
Received:January 17, 2023Revised:March 01, 2023
基金项目:
Standard Cold Source Based on Ice Slurry Refrigeration and Uncertainty Analysis
Liang Yongbiao1, Xu Geyao1, Xie Yuhang1, Zhou Long1, Zhong Wubin2, Li Bincheng3, Wu Jianghong1
(1.School of Mechanical and Automotive Engineering, South China University of Technology;2.Guangzhou Qunchuang Electrical Equipment Technology Co., Ltd.;3.Weikai Inspection Technology Co., Ltd.)
Abstract:
The problem of inconsistency between the measurement results of the cooling capacity of room air conditioners between environmental chambers still plagues China's air-conditioning industry and is a meteorological problem that easily leads to conflicts in international trade. A standard cold-source device that can calibrate laboratory measurement results of the enthalpy difference needs to be urgently studied. In this study, a standard cold-source device based on ice slurry refrigeration is proposed, including an ice slurry preparation system and a heat exchange system, based on a study of several mainstream cooling capacity measurement methods for room air conditioners and the research status of standard cold sources at home and abroad, combined with an in-depth understanding of the physical process of ice slurry refrigeration. Experimental research and refrigeration capacity uncertainty analysis are conducted to verify whether the standard cold-source device could calibrate the enthalpy difference laboratory. The experimental results show that the relative uncertainty of the measured cooling capacity of the standard cold-source device in the enthalpy difference chamber can reach 1.2% when setting 0 ℃ on the ambient side and setting the standard cooling condition on the room side with mass flow rate of 70 g/s, which is approximately 1/3 of the air enthalpy method and can be used as a standard cold source to calibrate the cooling capacity measurement results of the enthalpy difference chamber, which can help improve the international competitiveness of the refrigeration industry.
Key words:  ice slurry refrigeration  standard cold source  enthalpy difference chamber  air-enthalpy test method  calibration  relative uncertainty

用微信扫一扫

用微信扫一扫