罐式冷藏集装箱冷凝器的风道降阻设计
许尹慧子1, 陈炫丞1, 庄大伟1, 丁国良1, 徐 玮2, 陆晔飞2
0
(1.上海交通大学制冷与低温研究所;2.中集集安瑞环科技股份有限公司)
摘要:
罐式冷藏集装箱是目前运输低温液体的最主要途径,其制冷系统出风口被液罐遮挡,导致罐箱制冷系统能效低,需在有限的安装空间下提升罐箱制冷系统能效。本文提出通过优化冷凝器风道结构与管路排布来减小风道总阻力损失、提升冷凝器风量的思路,来提升系统能效;通过优化出风口形状、分布和尺寸,保证冷凝器的出风口在受到一定遮挡的条件下也能够有足够的风量;通过优化冷凝器管路布置,在保证换热能力不下降的条件下进一步降低冷凝器阻力损失、提升风量。对上述风道降阻设计方案的测试结果表明,针对冷凝器风道结构和管路排布的优化可提升罐箱制冷系统能效25.0%,说明本文提出的冷凝器风道降阻设计方案能够有效提升罐箱制冷系统的能效。
关键词:  罐式冷藏集装箱  冷凝器  风道降阻  管路排布  能效
DOI:
Received:June 24, 2022Revised:October 30, 2022
基金项目:
Reducing Flow Resistance of Air Duct for Condenser in Refrigerated Tank Containers
Xu Yinhuizi1, Chen Xuancheng1, Zhuang Dawei1, Ding Guoliang1, Xu Wei2, Lu Yefei2
(1.Institute of Refrigeration and Cryogenics, Shanghai Jiao Tong University;2.CIMC Safeway Technologies Co., Ltd.)
Abstract:
Refrigerated tank containers are currently the primary method of transporting cryogenic liquids. The air outlet of the refrigeration system is blocked by the liquid tank, resulting in low energy efficiency of the refrigeration system. This study aims to improve the energy efficiency of the refrigeration system for a tank container with a limited installation space. The resistance loss of the air duct is reduced and the air volume of the condenser is increased by optimizing the condenser air duct structure and pipeline arrangement, thereby improving energy efficiency. By optimizing the structure of the air outlet, sufficient air volumetric flow rate can be achieved under blocked conditions. By optimizing the pipeline arrangement, the resistance loss of the condenser is reduced, and the air volumetric flow rate is increased. The test results of the above system show that air duct structure optimization and condenser flow path optimization can improve the energy efficiency of the refrigeration system by 25.0%, indicating that the proposed optimization scheme can effectively improve the energy efficiency of the refrigeration system for tank containers.
Key words:  refrigerated tank container  condenser  air duct resistance reduction  flow path arrangement  energy efficiency