不同气候区太阳能-空气源热泵热水系统运行性能评价
郭宏伟1, 王宇1, 高文学2, 李志强3
0
(1.天津城建大学能源与安全工程学院;2.中国市政工程华北设计研究总院有限公司;3.广东万和新电气股份有限公司)
摘要:
本文运用非稳态制热实验方法测试空气源热泵在典型工况下的能效系数,测试不同日照强度下太阳能平板集热器的热效率,分析户用太阳能-空气源热泵热水系统在3~5人典型住宅用户热水负荷下的运行性能;选取不同气候区的代表城市,结合典型年气象数据,评价该系统在不同地区的太阳能贡献率和热水系统全年能效系数(APF)。得出:寒冷、夏热冬冷、夏热冬暖和温和地区热泵机组单独运行时系统APF分别为3.03、3.34、3.79、3.28;4个地区太阳能年贡献率分别为29.82%、32.07%、29.58%、38.62%,太阳能-空气源热泵组合系统APF分别可达3.67、4.06、4.39、4.45。
关键词:  空气源热泵  太阳能集热器  热水系统  年能效系数  不同气候区
DOI:
Received:April 12, 2018Revised:July 30, 2018
基金项目:国家自然科学基金(51606124)资助项目。
Performance Evaluation of Solar-air Source Heat Pump Hot Water System in Different Climatic Zones
Guo Hongwei1, Wang Yu1, Gao Wenxue2, Li Zhiqiang3
(1.School of Energy and Safety Engineering, Tianjin Chengjian University;2.North China Municipal Engineering Design & Research Institute Co., Ltd.;3.Guangdong Vanward New Electric Co., Ltd.)
Abstract:
To obtain the applicability and operation superiority of the solar-air source heat pump hot water system in different regions, the operation performance and energy efficiency coefficient of the air source heat pump unit and solar collector unit were tested through experiments under typical conditions. Tianjin, Shanghai, Guangzhou, and Kunming were selected for cold, hot-summer and cold-winter, hot-summer and warm-winter, and temperate regions, respectively. With the consideration of Chinese habits on domestic hot water, the performance of the heat pump system was analyzed in different areas for a typical family with 3~5 persons. The annual performance factor (APF) of a hot water system in different regions is calculated based on the weighted annual meteorological data of different cities. It is concluded that the APF of the hot water system is 3.03, 3.34, 3.79, and 3.28 in cold, hot-summer and cold-winter, hot-summer and warm-winter, and temperate regions, respectively, and the annual contribution rate of solar energy in the four regions is 29.82%, 32.07%, 29.58%, and 38.62%, respectively. The APF of the combination system can reach 3.67, 4.06, 4.39, and 4.45, respectively.
Key words:  air source heat pump  solar collector  hot water system  APF  different climate zones