Explicit Expressions for Rapid Evaluation of APF in Variable-frequency Air Conditioners
The determination method for the annual performance factor (APF) of the air conditioner energy efficiency index given in the national standard involves a series of evaluations and nested calculations
and the process is complex. The objective of this study is to convert the APF calculation formulas given in the new National Standard GB 21455—2019 into explicit calculation expressions
meeting the requirements for convenient APF calculation. The adopted method is as follows: first
the four intermediate variables of the APF are simplified by directly substituting independent variables; then
the process of determining the calculation interval and segmental calculation is simplified by means of numerical fitting; finally
the APF explicit expressions are obtained by substituting the explicit expressions of the four intermediate variables into the APF definition. The developed APF explicit expressions apply to variable-frequency air conditioners with different rated cooling capacities with good accuracy. Based on the definition of the APF in the National Standard
the calculation errors of the explicit expression for the 5-test working conditions and 7-test working conditions are 0.73% and 1.17%
Analysis on APF Calculation Problem Caused by the Optional Method to Obtaining Performance Parameters of Low-temperature Intermediate Refrigeration Condition in GB 21455—2019
Research on Key Parameters of a Building-Load Model for Dynamic Performance Measurement of Air Conditioner
Comparison and Development Trends of Energy Efficiency Characterization Methods for Room Air Conditioners in China and ASEAN Countries
A Method to Evaluate APF for Room Air Conditioner with on/off Compressor by Using Rated Performance Data
Experimental Research on the Room Air Conditioner with Thermoelectric Subcooler
Related Author
Cheng Jianhong
Wu Guoming
Shi Wenxing
Wen Chengyu
Gao Yuping
Han Xing
Cheng Jianhong
Cai Ning
Related Institution
Chinese National Institute of Standardization
Midea Corporate Research Center
China National Institute of Standardization
School of Energy and Environment, University of Science and Technology Beijing