Data Center Cooling Technology

 

(一)Performance Evaluation of Data Center Cooling System

1Comprehensive COP Evaluation System for Energy Efficiency of Data Center Cooling System

Cheng Hengda, Chen Huaruin, Shao Shuangquan, Li Zhengfei, Cheng Xiangdong

Vol.41, Iss.6, 2021, Pages 77-84

doi:10.3969/j.issn.0253-4339.2020.06.077

 

2Current Status and Prospects of Two-phase Cooling for Data Centers

Li Fangning, Cao Haishan

Vol.43, Iss.3, 2022, Pages 28-36

doi:10.3969/j.issn.0253-4339.2022.03.028

 

3Experimental Test on Server Power Consumption Based on Performance Testing Software

Xu Xin, Bai Xuelian, Jin Chaoqiang

Vol.42, Iss.3, 2021, Pages 100-106

doi:10.3969/j.issn.0253-4339.2021.03.100

 

(二)Chip/Server Cooling Technology

4Simulation Comparison of Different Cooling Modes of Blade Server in Data Centers

Liu Shengchun, Liu Zhang, He Wei, Jia Ziang, Luo Yilin, Zhu Kai

Vol.40, Iss.5, 2019, Pages 90-95

doi:10.3969/j.issn.0253-4339.2019.05.090

 

5Optimal Design of CPU Water-cooled Radiator in a Data Center Server

Zhu Kai, Liu Zekuan, He Wei, Chai Xiang

Vol.40, Iss.2, 2019, Pages 36-42

doi:10.3969/j.issn.0253-4339.2019.02.036

 

6Effect of Different Electronic Cooling Liquid on the Performance of Immersion Phase Change Cooling System

Wu Xilei, Liu Ying, Ni Hang, Huang Jiongliang, Guo Haowen, Zhuang Yuan, Han Xiaohong

Vol.42, Iss.4, 2021, Pages 74-82

doi:10.3969/j.issn.0253-4339.2021.04.074

http://www.zhilengxuebao.com/zlxb/ch/reader/create_pdf.aspx?file_no=20210410

 

(三)Vapor Compression/Loop Heat Pipe System

7Application of CO2 Two-phase Thermosyphon Loop in Data Centers

Tong Zhen, Li Xiaorui

Vol.42, Iss.1, 2021, Pages 67-73

doi:10.3969/j.issn.0253-4339.2021.01.067

 

8Experimental Study on Compressor-driven Loop Heat Pipe for Data Center Cooling

Wang Fei, Shao Shuangquan, Zhang Hainan

Vol.41, Iss.4, 2020, Pages 89-96

doi:10.3969/j.issn.0253-4339.2020.04.089

 

9Performance Analysis of Gas-Pump-Driven Free-cooling Unit in a Small Data Center

Xue Lianzheng, Ma Guoyuan, Zhou Feng, Li Fuping, Yan Xianghui, Jiang Mingjian

Vol.40, Iss.4, 2019, Pages 1-9

doi:10.3969/j.issn.0253-4339.2019.04.001

 

10Experimental Research on Air Conditioning System of a Computer Room Based on Refrigerant Pump Pressurization

Lin Yucong, Liu Jinping, Xu Xiongwen, Liu Zhen, Li Guoli

Vol.41, Iss.5, 2020, Pages 83-88

doi:10.3969/j.issn.0253-4339.2020.05.083

 

11Experimental Study on Operation Performance of Composite Cooling System with Evaporative Cooling Heat Pipe and Vapor Compression for Data Center

Xue Da, Han Zongwei, Sun Xiaoqing, Cheng Xinlu, Li Xiuming

Vol.43, Iss.1, 2022, Pages 26-34

doi:10.3969/j.issn.0253-4339.2022.01.026

 

12Experimental Investigation on Dew Point Indirect Evaporative Cooling System Combined with Mechanical Refrigeration for Data Center

He Hongxia, Huang Xiang, He Huaming, Chu Junjie, Sun Tiezhu

Vol.41, Iss.6, 2020, Pages 71-76

doi:10.3969/j.issn.0253-4339.2020.06.071

 

(四)Cold Storage, Heat Recovery and Optimization of Refrigerator

13Experimental Research and Performance Analysis of a Phase-change Cold Thermal Energy Storage Unit for Emergency Cooling in Air-cooled Modular Data Centers

Huang Bin, Zheng Zi'ao, Lu Gaofeng, Zheng Chunyuan, Li Bin, Zhai Xiaoqiang

Vol.43, Iss.6, 2022, Pages 41-48

doi:10.3969/j.issn.0253-4339.2022.06.041

 

14Experimental Study on Silica Gel-water Adsorption Refrigeration System for Waste Heat Recovery in Data Center

Peng Jiajie, Ge Tianshu, Pan Quanwen, Wang Ruzhu

Vol.40, Iss.4, 2019, Pages 59-65

doi:10.3969/j.issn.0253-4339.2019.04.059

http://www.zhilengxuebao.com/zlxb/ch/reader/create_pdf.aspx?file_no=20190409

 

15Optimal Load Allocation of Multiple Chiller System Based on Association Rules

Wang Xianglan, Jin Xinqiao, Lü Yuan, Jia Zhiyang

Vol.43, Iss.1, 2022, Pages 35-45

doi:10.3969/j.issn.0253-4339.2022.01.035

 

 

用微信扫一扫

用微信扫一扫