Cite this article
  •    [Click To Copy]
  •    [Click To Copy]
【Print This Page】 【Download PDF Full Text】 View/Add CommentDownload reader Close

←Previous Article|Next Article→

Back Issue    Advanced Search

This Article Has Been:Browse 1708 Times   Download 2069 Times QR code information in this article
Scan Up The Code!
采用非共沸混合工质机械过冷的跨临界CO2制冷循环性能分析
代宝民1, 刘圣春1, 孙志利1, 马牧宇1, 陈启2, 马一太3
0
(1.天津商业大学天津市制冷技术重点实验室;2.天津三电汽车空调有限公司;3.天津大学热能研究所)
摘要:
本文提出了采用非共沸混合制冷剂作为机械过冷循环工质对气体冷却器出口的CO2流体进行过冷的新型CO2制冷循环。在最优排气压力和最优过冷度下循环取得最大COP。最大COP、最优排气压力和过冷度与混合制冷剂的温度滑移密切相关。当选取合理温度滑移的混合工质作为机械过冷循环的制冷剂时,可明显提升CO2制冷循环能效,降低排气压力。与基本CO2制冷循环相比,在蒸发温度为﹣40 ℃、环境温度为35 ℃时,采用R32/R152a(40/60)循环总COP可提升46.53%,CO2排气压力可降低2.758 MPa。总COP的提升程度受混合制冷剂的温度滑移影响显著,推荐机械过冷循环使用温度滑移合理的混合制冷剂。在温暖和炎热的气候地区以及冷冻冷藏等低温应用领域,采用非共沸混合制冷剂机械过冷跨临界CO2制冷循环整体性能的提升更加显著。
关键词:  CO2  非共沸工质  机械过冷  制冷循环  温度滑移
DOI:
Received:November 21, 2017
基金项目:国家自然科学基金(51806151)和天津市高等学校自然科学研究(No.160018)项目资助。
Performance Analysis of Transcritical CO2 Refrigeration Cycle with Mechanical Subcooling Employing Zeotropic Mixture as Working Fluid
Dai Baomin1, Liu Shengchun1, Sun Zhili1, Ma Muyu1, Chen Qi2, Ma Yitai3
(1.Tianjin Key Laboratory of Refrigeration Technology, Tianjin University of Commerce;2.Tianjin Sanden Auto Air-conditioning Co., Ltd.;3.Thermal Energy Research Institute, Tianjin University)
Abstract:
A novel transcritical CO2 refrigeration cycle by utilizing zeotropic mixture as working fluid for the mechanical subcooling (MS) cycle is proposed in this study, which can be utilized to subcool the CO2 fluid flowing from the gas cooler. A maximum overall COP is achieved at the optimum discharge pressure and optimum subcooling degree. The results indicate that the maximum overall COP, optimum subcooling degree, and discharge pressure are closely related to the temperature glide. Additionally, the energy efficiency of CO2 refrigeration cycle is improved efficiently and the high pressure is reduced significantly when mixtures with proper temperature glide are used as the refrigerant of MS cycle. When compared with the base CO2 refrigeration cycle, the overall COP is enhanced by 46.53%, and discharge pressure is reduced by 2.758 MPa at an evaporation temperature of ﹣40 ℃ and ambient temperature of 35 ℃ when R32/R152a (40/60) is employed. The overall COP enhancement is significantly linked to the temperature glide. Furthermore, the thermal performance of the overall cycle is more significantly enhanced for hot or warm climate regions or relatively low evaporation temperature applications such as freezing and cold storage.
Key words:  CO2  zeotrope working fluid  mechanical subcooling  refrigeration cycle  temperature glide

用微信扫一扫

用微信扫一扫