Wang Jiazheng, Ma Guoyuan, Yu Guoxin, et al. Experimental Study on Household Air-source Heat Pump Water Heater with Flash Tank[J]. Journal of refrigeration, 2022, 43(6).
DOI:
Wang Jiazheng, Ma Guoyuan, Yu Guoxin, et al. Experimental Study on Household Air-source Heat Pump Water Heater with Flash Tank[J]. Journal of refrigeration, 2022, 43(6). DOI: 10.3969/j.issn.0253-4339.2022.06.100.
Experimental Study on Household Air-source Heat Pump Water Heater with Flash Tank
The experimental system of household air-source heat pump water heater with flash tank was set up
and its operation perform- ance at different temperatures was studied in the environmental control room
and compared with the single-stage compression system. The results show that the heating capacity and heating COP of the household air-source heat pump water heater with flash tank are greater than that of the single-stage compression system
and the heating capacity increases 21. 3% when the ambient temperature is -15 ℃ . The heat- ing time of air-source heat pump water heater with flash tank system is shortened by 20. 1% compared with that of single-stage system un- der the same water volume and initial and ending temperatures. The discharge temperature of the compressor is reduced by 11. 3 ℃
which ensures the operation safety of the unit. The calculation of APF shows that the system of flash tank replenishment is better in the ar- ea with lower ambient temperature.