Research on the Annual Performance Factor Differences of Inverter Air Conditioner using Different Refrigerants
China’s inverter air conditioner efficiency standard (GB21455—2013) adopts a single set of annual performance factor (APF) values to evaluate inverter heat-pump air conditioner charged with different types of refrigerants. Obviously
neglecting the refrigerant classification is a flaw in the standard. Thus
we obtained two types of running-time curves from meteorological statistics and standard data. Furthermore
on the basis of these curves
the APF of several inverter air conditioner with different refrigerants were analyzed in terms of the same environmental impact (the total equivalent warming impact (TEWI) was chosen). The results show that the APF values of the R290 equipment were relatively lower than those of R22 and R410A under the same environmental impact. According to the standard data results (air conditioner with 2 HP cooling-capacity)
the APF differences between these refrigerants were up to 0.57 and 0.59
respectively. Finally
a refrigerant-classification evaluation in terms of the energy efficiency standards was performed. In addition to the indirect environmental influence on the equipment energy efficiency
the direct effect of refrigerants should also be considered.
Experimental Study on Flow Boiling Heat Transfer and Pressure Drop Characteristics of R245fa in a Dimpled Flat Tube
Research Progress in Composite-enhanced Flow Boiling Heat Transfer for Refrigerants
Effect of Flow Resistance in Adiabatic Part on the Thermal Performance of CO2, R134a, and R410A Two-phase Thermosyphon Loops
Analysis on APF Calculation Problem Caused by the Optional Method to Obtaining Performance Parameters of Low-temperature Intermediate Refrigeration Condition in GB 21455—2019
Current Situation of Refrigerant Recovery and Reclaim
Related Author
Feng Ye
Ding Puxian
Shao Shuangquan
Tian Xingwang
Xu Zhentao
Zhang Kun
Chen Cong
Xu Shiming
Related Institution
College of Modern Logistics, Guangzhou Panyu Polytechnic
School of Energy and Power Engineering, Huazhong University of Science and Technology
College of Ocean and Civil Engineering, Dalian Ocean University
School of Energy and Power Engineering, Dalian University of Technology
School of Environmental and Municipal Engineering, Qingdao University of Technology