Effect of Different Diameter on Performance of Air-conditioning Umbrella with Semiconductor Refrigeration
Aiming at the problem of large volume and difficulty in the maintenance of compression-type air-conditioning umbrellas
an air-conditioning umbrella with semiconductor refrigeration is introduced. A test bench was built to measure the temperature and flow field in the umbrellas with different diameters ( 36 cm
38 cm
and 40 cm). Based on the Peltier effect and the structural characteristics of the air conditioning umbrella
the lower air supply mode was applied within the air-conditioning umbrella with semiconductor refrigeration. Experimental results indicate that the air speed in the umbrella with a diameter of 38 cm is between 0.23 m/s and 0.47 m/s
and the maximum temperature difference between air-conditioned area and ambient environment is 3.04 ℃
which can thus create a comfortable local environment.