Shen Jiang, Bian Yujun, Guo Xinwei. Experimental Study on the Effect of Cold-end Aperture on the Performance of Vortex Tube[J]. Journal of refrigeration, 2017, 38(6).
DOI:
Shen Jiang, Bian Yujun, Guo Xinwei. Experimental Study on the Effect of Cold-end Aperture on the Performance of Vortex Tube[J]. Journal of refrigeration, 2017, 38(6). DOI: 10.3969/j.issn.0253-4339.2017.06.087.
Experimental Study on the Effect of Cold-end Aperture on the Performance of Vortex Tube
The influence of different cold end orifice diameter on the performance of vortex tube was studied using the test bench. In the 0.3-0.5 MPa range of inlet pressure
the effect of cold end pore size on the temperature drop
the characteristics of refrigeration capacity
the efficiency of the temperature and the COP characteristics were analyzed. The experimental results showed that the cold end orifice diameter on the vortex tube has a great impact on performance
and there exists a cold end orifice diameter of a vortex tube which makes the cold end temperature drop and refrigeration capacity reach the maximum. Under the current conditions of the vortex tube
the optimal diameter of the cold end orifice is 5 mm
and the ratio between the best cold end orifice diameter and the best hot end diameter is 0.5.