Zhang Genxuan, Wang Lu, Zhang Xianfeng, et al. Experimental Research on a Cooling System with Two Phase Closed Thermosyphon Loop for a DAM[J]. Journal of refrigeration, 2016, 37(1).
DOI:
Zhang Genxuan, Wang Lu, Zhang Xianfeng, et al. Experimental Research on a Cooling System with Two Phase Closed Thermosyphon Loop for a DAM[J]. Journal of refrigeration, 2016, 37(1). DOI: 10.3969/j.issn.0253-4339.2016.01.090.
Experimental Research on a Cooling System with Two Phase Closed Thermosyphon Loop for a DAM
Two phase thermosyphon loop has a good potential of application in cooling of electronic equipment with high power source because of its relatively high efficiency of heat dissipation performance. To solve the cooling problem of a DAM with four channels
this paper designs a prototype of two phase closed thermosyphon cooling system. The starting characteristic of the system
the influence of the refrigerant charge and working inclination angle on its heat dissipation performance are investigated experimentally in this paper. The results show that the structure and heat dissipation performance of the system match the requirement. It also can be found that the starting characteristic and the working performance of the system are very good. In addition
a 1600W module with local heat flux near 100W/cm2 is cooled very well by the system in this paper.