Experimental Research on Performance of Small Room Air Conditioner with R290[J]. Journal of Refrigeration, 2006, 27(4): 26-30.
DOI:
Experimental Research on Performance of Small Room Air Conditioner with R290[J]. Journal of Refrigeration, 2006, 27(4): 26-30. DOI: 10.3969/j.issn.0253-4339.2006.04.007.
Experimental Research on Performance of Small Room Air Conditioner with R290
The performance of small room air conditioners using R290 as a substitute for R22 was studied in this study.Tests were conducted for a KF-26GW/K air conditioner and a high EER KFR-27GW/E air conditioner.The charging quantity
the lengths of single capillary and double capillary
and the performance of regenerative cycle with R290 were investigated
respectively.The test results show that the optimum charging quantity of R290 is about 50% of the original charging quantity of R22
and the refrigeration capacity can reach about 97.2% of the R22 system and the EER can increase by up to 12.6%.In addition
the refrigeration capacity of regenerative cycle with R290 will be little lower than that of the R22 system.