Research on Optimization Design of Refrigeration System for Direct Cooling Refrigerator[J]. Journal of refrigeration, 2005, (1).
DOI:
Research on Optimization Design of Refrigeration System for Direct Cooling Refrigerator[J]. Journal of refrigeration, 2005, (1). DOI: 10.3969/j.issn.0253-4339.2005.01.013.
Research on Optimization Design of Refrigeration System for Direct Cooling Refrigerator
摘要
冷冻室蒸发器采用多层换热片的复合立体结构
在S型制冷盘管壁外侧固定套装翅片
增加冷冻室顶部和低部两个高温区制冷量.将冷冻室按1:1划分出变温室
通过其中温度传感器控制双稳态电磁阀通断实现制冷剂回路切换
将变温室按冷冻、软冷冻、冷藏使用
也可关闭.通过横、竖盘管混排结构的丝管式冷凝器设计
借助制冷系统压缩机、冷凝器、蒸发器负荷匹配及其与毛细管制冷剂流量匹配
通过防凝露管走向及位置设计、蒸发器管道位置及走向布置和回气换热器设计
研制的BCD-186CHS直冷电冰箱最大负荷日耗电0.39度
在变温室为节能状态时耗电在0.35度以下
最低达0.31度.
Abstract
Composite and stereoscopic structure with laminated exchanger flake was used on evaporator of freezing chamber.Wing-flakes were fixed outside the refrigerant pipe coil with a S type to increase the refrigeration capacity of the top part and the bottom part of freezing chamber. Freezing chamber was divided into variable temperature areas according to 1:1 proportion.A temperature sensor controls On-Off of an double steady states electro-magnetic valve so that cut-over of refrigerant circuit can be completed. Variable temperature areas might be used as freezing chamber
lower-degree freezing chamber
or cold storage chamber and also could be shut off. By the optimizing design of the condenser structure
direction and position of anti-condensation pipe and evaporator
circling-gas exchanger and by matching the load of compressor
condenser
and evaporator
a direct cooling refrigerator
BCD-186CHS
was recently developed. It consumes 0.39 kWh per day under the maximum load
and less than 0.35kWh even 0.31 kWh per day when the variable temperature chamber is operating under economy condition.