Experimental Study on a Refrigerant Charge Diagnostic Method for Multi-split Systems
This paper proposes a high-precision refrigerant charge diagnostic method based on active control, which effectively addresses the shortcomings of traditional passive diagnostic methods, such as low sensitivity to small deviations and susceptibility to interference from system operating conditions. The method actively anchors the core thermodynamic boundary conditions of the system and, based on the principle of mass conservation and heat transfer mechanisms, directionally converts variations in refrigerant charge into changes in liquid-phase retention within the condenser. The condenser outlet subcooling degree is thereby employed as the core characteristic parameter for quantitative diagnosis, and a standardized four-stage diagnostic procedure, including startup, coarse regulation, fine regulation, and measurement is established, with quantitative stability criteria. Cross-validation experiments covering six operating conditions and outdoor temperatures from 20 ℃ to 45 ℃ were conducted in an enthalpy difference laboratory using two multi-split units with nominal cooling capacities of 16 kW and 18 kW. The results demonstrate that, within the charge ratio range of 85%-105%, the subcooling degree exhibits a strictly monotonic increasing trend with respect to refrigerant charge. The subcooling difference between 100% and 90% charge levels remains above 6 °C across all test conditions, and this relationship remains stable across different unit models and outdoor temperatures. The diagnostic model constructed from this relationship can accurately identify refrigerant charge deviations as low as 5%, providing a reliable technical solution for online operational diagnostics and early fault warning in multi-split air-conditioning systems.
Tian Bo , Peng Peng , Wu Qingzhuang , et al . Fast load forecasting model for intelligent control of VRF heat pump air conditioning systems [J]. Journal of HV&AC , 2025 , 55 ( 12 ): 105 - 113 .
Huang Qianyun , Chen Huanxin , Sun Shaobo , et al . Fault detection and diagnosis of refrigerant charge for multi-split systems based on support vector machine [J]. Journal of HV&AC . 2018 , 48 ( 1 ): 91 - 95 .
Liu Qian , Li Zhengfei , Ding Xinlei , et al . Fault type identification and fault refinement diagnosis model of variable refrigerant flow system [J]. Journal of Refrigeration , 2021 , 42 ( 2 ): 118 - 126 .
Wei Wentian , Li Zhengfei , Wang Yuzhou , et al . Boosting-based refrigerant charge fault diagnosis integration model of variable refrigerant flow system [J]. Journal of Refrigeration , 2020 , 41 ( 2 ): 70 - 78 .
He Jinning , Xu Tingxi , Huang Wei , et al . Adaptive fault diagnosis model of air conditioning system based on eXtreme gradient boosting algorithm [J]. Chinese Journal of Refrigeration Technology , 2022 , 42 ( 2 ): 25 - 31 .
Zhang Xue , Cheng Yunxi , Chen Huanxin , et al . Refrigerant charge fault diagnosis in VRF systems using Kolmogorov-Arnold networks and their convolutional variants: a comparative analysis with traditional models [J]. Energy and Buildings , 2025 , 336 : 115608 .
Zhang Li , Peng Youlun , Chen Huanxin , et al . Evaluation and parameter optimization of refrigerant charge fault detection models for multi-split systems [J]. Chinese Journal of Refrigeration Technology . 2023 , 43 ( 1 ): 37 - 42 .
Cai Yajun . Fault diagnosis model of air conditioning refrigerant shortage based on multidimensional curve fitting algorithm [J]. Refrigeration and Air Conditioning , 2023 ( 1 ): 92 - 96 .
Li Haorong , Braun J E . Development, evaluation, and demonstration of a virtual refrigerant charge sensor [J]. HVAC&R Research , 2009 , 15 ( 1 ): 117 - 136 .
Xun Weide , Li Shaobin , Tan Zehan , et al . A new fault diagnosis tactic for refrigerant charge amount based on discrete Hopfield neural network [J]. Chinese Journal of Refrigeration Technology , 2018 , 38 ( 3 ): 8 - 13 .
Liu Shurong , Zhou Yujue , Dai Chuanmin , et al . Refrigerant charge optimization in direct expansion air conditioning systems under variable operating conditions [J]. Applied Thermal Engineering , 2026 , 290 : 130108 .
GB/T 18837—2026 多联式空调(热泵)机组 [S]. (GB/T 18837 —
2026 Multi-split air-conditioning (heat pump) units [S].