A multi-connected air conditioner with refrigerant and water using hot water from district heating system for direct heating
|更新时间:2025-01-15
|
A multi-connected air conditioner with refrigerant and water using hot water from district heating system for direct heating
Journal of Refrigeration(2025)
作者机构:
1. 清华大学建筑学院,北京
2. 青岛海尔空调电子有限公司,青岛
作者简介:
基金信息:
DOI:
CLC:TU995;TU831.3
稿件说明:
移动端阅览
A multi-connected air conditioner with refrigerant and water using hot water from district heating system for direct heating. [J/OL]. Journal of refrigeration, 2025.
DOI:
A multi-connected air conditioner with refrigerant and water using hot water from district heating system for direct heating. [J/OL]. Journal of refrigeration, 2025.DOI:
A multi-connected air conditioner with refrigerant and water using hot water from district heating system for direct heating
direct expansion air conditioning systems are used for cooling
and the hot water from district heating networks is often used for heating
which requires two types of terminals. A multi-connected air conditioner with refrigerant and water using hot water from district heating system for direct heating is proposed in this study. Three-fluid heat exchangers are used in the indoor units of the system
which can use hot water from district heating system or heat pumps for room heating
achieving flexible switching between direct expansion air conditioning system and district heating system. Taking an office building in Beijing as an example
the air conditioning system is selected in the summer designed condition. The simulation model of the system is established
and the heating effect of the system during the heating season and transition season is analyzed. The results show that the user side water temperature required for the system during the heating season is less than 54 ℃; when using direct expansion system during the transition season for heating
the unit capacity is higher than the peak heating load during the transition season
and the energy efficiency exceeds 3.5 within 49% of the operating time. The system proposed in this article utilizes one terminal to ensure summer cooling and winter heating needs
and can use direct expansion system for heating after district heating system shutdown
simplifying the existing system form and improving heating comfort.
关键词
水氟互联机三介质换热器空调系统市政热网供暖
Keywords
multi-connected air conditioner with refrigerant and waterthree-fluid heat exchangerair conditioning systemdistrict heating systemroom heating