引用本文:[点击复制]
[点击复制]
【打印本页】 【在线阅读全文】【下载PDF全文】 查看/发表评论下载PDF阅读器关闭

←前一篇|后一篇→

过刊浏览    高级检索

本文已被:浏览 1207次   下载 1202 本文二维码信息
码上扫一扫!
采用非共沸工质机械过冷跨临界CO2热泵供暖性能分析
代宝民,张鹏,刘圣春,王铭慧,孙悦桐,王嘉豪,徐田雅慧,肖鹏
0
(天津商业大学天津市制冷技术重点实验室;天津市丹华宏业制冷技术有限公司)
摘要:
本文提出采用非共沸工质的机械过冷跨临界CO2热泵供暖系统,并建立系统热力学模型,与采用纯质的机械过冷跨临界CO2热泵系统进行对比。结果表明:在环境温度为-12 ℃、用户供回水温度为65/40 ℃条件下,采用大温度滑移非共沸工质R1234ze(E)/R601(60/40)时,系统COP高达2.45,相对采用纯质最高提升13.82%。采用非共沸工质可有效降低系统排气压力并获得较大过冷度,减小节流不可逆损失。使用R290/R601(70/30)时,最优排气压力可降低27.85%。非共沸工质的使用可有效改善过冷过程的温度匹配,使用R1234ze(E)/R601(60/40)时系统?效率相对纯质最高提升14.09%。较大的温度滑移及合理的温焓曲线凹凸性是机械过冷CO2热泵系统非共沸工质选取的两个重要原则,推荐选用R1234ze(E)/R601(60/40)。
关键词:  供暖  热泵  机械过冷  温度匹配    非共沸工质  CO2
DOI:
投稿时间:2021-03-06  修订日期:2021-06-09  
基金项目:国家自然科学基金(No. 51806151)资助项目,天津市自然科学基金项目(20JCQNJC00600)、天津市研究生科研创新项目(2020YJSS060)和大学生创新创业训练项目(202110069067)资助。
Performance of Transcritical CO2 Air-source Heat Pump Heating System with Mechanical Subcooling Using Zeotropic Refrigerant
Dai Baomin,Zhang Peng,Liu Shengchun,Wang Minghui,Sun Yuetong,Wang Jiahao,Xu Tianyahui,Xiao Peng
(Tianjin Key Laboratory of Refrigeration Technology, Tianjin University of Commerce)
Abstract:
In this study, a mechanical subcooling transcritical CO2 heat pump heating system using a zeotropic refrigerant is proposed. A thermodynamic model is developed for this system and compared with that using a pure refrigerant. The results indicate that the coefficient of performance employing R1234ze(E)/R601(60/40) with a large temperature glide is up to 2.45, which is 13.82% higher than that of the pure component, at an ambient temperature of -12 ℃ and supply/return water temperatures of 65°C/40°C. The discharge pressure of the CO2 system can be efficiently reduced, and a higher subcooling degree is achieved using a zeotropic refrigerant; hence, the throttling irreversible loss decreases. The optimal discharge pressure is reduced by 27.85% using R290/R601(70/30). The temperature match in the subcooling process can be efficiently improved, and the exergy efficiency is up to 14.09% higher than that of the pure refrigerant component when using R1234ze(E)/R601(60/40). The relatively large temperature glide and suitable concave-convex characteristic of the temperature-enthalpy curve are the two key principles for zeotropic refrigerant selection used for CO2 heat pump systems with mechanical subcooling. Finally, the utilization of R1234ze(E)/R601(60/40) is recommended.
Key words:  heating  heat pump  mechanical subcooling  temperature matching  zeotropic refrigerant  CO2

用微信扫一扫

用微信扫一扫